Insulation resistance testing guide chauvin arnoux. Insulation resistance testing of low voltage cables in the. The insulation resistance test is an electrical test which uses a certain type and level of voltage 500v d. There are two schools of thought regarding the voltage to test insulation at. A 1954 diacam2 equipped with a 160 x 120 detector and a 38x28 wideangle lens, the c. Hipot testing verifies the integrity of highvoltage ac primary wire insulation in an electrical.
Understanding insulation resistance testing pdf 0206 rev. Consult the insulation resistance test equipment manual or manufacturer for insulation resistance testing procedures and recommended safety guidelines. To evaluate a number of test results on the same piece of equipment, you have to conduct the test the same way and under the relatively same. It is the product of the test voltage, the test current and the cosine of theta. Insulation resistance testers can be used to determine the integrity of windings or cables in motors, transformers, switch gear, and electrical installations.
The measured resistance indicates the condition of the insulation between two conductive parts. How to test three phase ac motors learning electrical. Gpt flange isolation kit isolation test procedures for a dry. If the motor is not put into operation immediately upon arrival, it is important to protect it against external factors like moisture, high temperature and impurities in order to avoid damage to the insulation. Ieee recommended practice for testing insulation resistance. Place one megger probe to the any mounting bolt on the breaker box to test for grounding continuity, then touch the.
This test is done by testing the insulation at two or more voltages and comparing the results. Insulation resistance test or megger test procedures with circuit diagram in this article we will go through megger test first of all i want to say both insulating resistance tests and megger test are same. Ieee std 432000 recommends a procedure for measuring insulation resistance of armature and field windings in rotating machines rated 1. By examining the variations of the insulation value according to the test voltage application time, it is possible to assess the quality of the insulation. A catalogue, for quick reference, of the range of megger test instruments for the maintenance of electrical power systems. Insulation resistance testing should be done by qualified personnel, familiar with both insulation resistance testing and with the safe operation of the test equipment. To test the insulation integrity you will need a megohmmeter or hipot rated to produce the specified maximum test voltage. Understanding insulation resistance testing pdf 0712 technical assistance 800 34391. Use a multimeter or the voltage measurement function on the megohmmeter to make sure there is no power applied to the tested circuit. Apr 12, 2014 this test method is sometimes also referred to as an absorption test because it is based on the absorption effect of good insulation compared to that of moist or contaminated insulation, which gives you a clearer picture of insulation quality even when a spot reading indicates an acceptable condition.
Ieee recommended practice for testing insulation resistance of rotating machinery 1. Well learn how to identify windings, check windings resistance and insulation resistance. Because electrical insulation will exhibit dynamic behavior during the course of your test. It also serves as the best guide to indicate the health of the equipment. Electrical insulation starts to age as soon as its made. It is commonly used in the industry for acceptance testing prior to energizing the cable and for maintenance testing programs. Megger test procedure manufactured goods electromagnetism. The insulation resistance test is the second test required by the electrical safety testing standards the insulation resistance test consists in measuring the insulation resistance of a device under test, while phase and neutral are short circuited together. Insulation step voltage test an insulation step voltage test is a test that creates electrical stress on internal insulation cracks to reveal aging or damage not found during other motor insulation tests. The amount of current depends on the amount of voltage applied, the.
Additional notes about using a megger insulation tester 33. Gpt flange isolation kit isolation test procedures for a dry system. How to measure insulation resistance with a 1587 youtube. An insulation test is carried out to test the integrity of the insulation between conductors. Pdf this paper consist the specification of transformer and its procedure of measurement of.
A megger insulation resistance tester is especially useful when you have carried out electrical work on your home and want to make sure you didnt damage insulation or make a wiring mistake. The hipot test the dielectric voltagewithstand test is commonly known as the hipot test. Ieee std 1122004 revision of ieee std 1121996 ieee standard test procedure for polyphase induction motors and generators sponsor electric. It is typically used for test specimen that have small capacitance and as a result the power factor tan delta of the test circuit is rather high. Standard for acceptance testing specifications for. To effectively test the motor, you must disconnect the field coils where possible.
Which help to find the short circuit problems in the circuit. Insulation resistance or ir test is carried out by maintenance engineers to ensure the healthiness of the overall insulation system of electrical equipment it reflects the presence or absence of harmful contamination, dirt, moisture, and gross degradation. After insulating the equipment with calcium silicate mineral wool mattress, all voids in the joints shall be filled with moldable insulation loose mineral wool respectively. Performed by stressing the insulation of the product far beyond what it would encounter during normal use. For a three phase motor, insulation resistance is usually measured between each motor winding or phase and between each motor phase and motor frame earth using an insulation tester or megger. If no evidence of distress or insulation failure is observed by the end of the total time of voltage. Using ohms law vir, we can compute the value of the resistance. Figure 1 shows different insulation resistance values of certain wire segments, measured at the end of the damage phases 2 and 5. The test measures the insulation resistance between the phases andor between phase and ground. Section 7 of the ansineta standard for acceptance testing specifications for electrical power equipment and systems may be reproduced and used on a cut and paste basis for the particular type of equipment to be tested.
Motors are susceptible to the gradual failure of their insulation resistance. A 1954 camera is ideal for all applications in the building, electrical maintenance and mechanical maintenance sectors. Learn how insulation resistance test is done developed early in the 20th century, the insulation resistance ir test is the oldest and most widely used test for assessing the quality of insulation. There are three different tests that can be performed. In this video you will find out how to test 3phase induction motor. Megger insulation tester calibration procedure megger insulation tester is measuring resistance by generating a voltage. It reflects the presence or absence of harmful contamination, dirt, moisture, and gross degradation. This measurement is performed using an insulation tester, also called a megohmmeter. Facilities instructions, standards, and techniques volume 32 testing and maintenance of highvoltage bushings facilities engineering branch denver office denver, colorado internet version of this manual created august 2000 the appearance of the internet version of this manual may differ from the original, but the contents do not. Insulation power factor testing of power transformers.
Inspection and test procedures for rotating machinery. Pdf measurement of winding resistance and insulation. Cables and conductors should be tested and maintained on a threeyear cycle at minimum. If the motor is kept in a place with high humidity, a periodical inspection is necessary. How to measure insulation resistance with a 1587 looking for an extraordinary insulation multimeter with great features that every electrician needs. Wire and cable manufacturers use the insulation resistance test to track their insulation manufacturing processes, and spot developing problems before process. Performed by stressing the insulation of the product far. Megger guide to electrical insulation testing pdf instrumart. While the dielectric voltage withstand test is widely used, the real objective of the test is often misunderstood, which may lead. Electrical test technical guides megger supporttechnicallibrary.
Proof test voltage equations for rotating machines proof test procedure to conduct an installation proof test, use the following procedure. Mar 28, 2018 in this video you will find out how to test 3phase induction motor. To evaluate a number of test results on the same piece of equipment, you have to conduct the test the same way and under the relatively same environmental parameters, each and every time. Understanding insulation resistance testing aemc instruments. It will usually show the amount of moisture, the leakage current no the moist or dirty areas of the insulation, and winding faults and deterioration. The megger company registered the name megger in may 1903 and today offers a wide variety of ir testers.
Ir value will be usually high several hundred megaohms for a dry insulation system. How to test a threephase motor with a megger by eric w. Aemc instruments testing methods and interpretation of the results shorttime or spotreading measurement this is the simplest method. Ieee std 432000 recommends a procedure for measuring insulation resistance of armature and field windings in rotating machines.
Com reference manual applications guide delta 4000 12 kv insulation diagnostic system zmah02e. Megger insulation tester calibration procedure calibration. Ieee std 1122004, ieee standard test procedure for. Gpt flange isolation kit isolation test procedures for a. A megger is able to measure highvoltage resistance values. The insulation resistance test is the second test required by the electrical safety testing standards. Nov 19, 20 how to measure insulation resistance with a 1587 looking for an extraordinary insulation multimeter with great features that every electrician needs. This document will focus only on the tests that are of importance for field installers which are described as installation and maintenance tests. Regular insulation resistance testing is one of the most cost effective, nondestructive methods of identifying ageing in electrical equipment.
Isbn 07389785 ss95211 no part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher. If no evidence of distress or insulation failure is observed by the end of the total time of voltage application during the dielectric withstand test, the test specimen is considered to have passed the test. Each day application of insulation should be weather proofed overnight by either. Importance of insulation resistance test or megger test. Insulation resistance testing is a nondestructive test procedure. The test does have a limit of between 500 and volts, so it may not always be able to detect some insulation punctures. Designed to verify that the insulation of a product is adequate enough to withstand high voltage. The following is a summary of insulation resistance ir testing commonly referred to as megger testing of low voltage cables rated less than 5 kv, recognized by nexans. Understanding insulation resistance testing pdf 0712. Facilities instructions, standards, and techniques volume 32. It is practically impossible to determine rules for the actual minimum insulation resistance value of a motor because resistance varies according to method of construction, condition of insulation material used, rated voltage, size and type. Set the megohmmeter to 500 v and connect to measure the resistance of each winding lead to ground. The insulation of the wire samples is checked with a wet insulation test, a test procedure, which is similar to a voltage withstand test according to astm d 3032 ast98.
When performing insulation tests on conductors and cable, apply the following procedure. Find here insulation testing and continuity, power protection, power transformer testing, power cable infrastructure, cable fault location, general electrical test. Insulation resistance test or megger test procedures with. Insulation resistance test of transformer is one of the most important transformer tests we can perform this test at factory or site this test can be classified under type test, routine test, precommissioning and commissioning tests, periodic maintenance transformer tests you can know more about transformer testing and its. The measured resistance has to be higher than the indicated limit from the international standards. Threephase dualvoltage motor insulation resistance testing threephase dualvoltage motors are used for most daytoday operations in todays industrial plants. During the testing procedure, the high dc voltage generated by pressing the test button will cause a small microamps current flow through the conductor and the insulation. Threephase dualvoltage motor insulation resistance testing. Since 80% of electrical maintenance and testing involves evaluating insulation integrity, the answer is very important.
The complete guide to electrical insulation testing. Insulation resistance tests should be performed more frequently for systems that show deterioration of insulation material. A guide to diagnostic insulation testing above 1 kv. With a little recordkeeping and common sense, however, you can get a good picture of the insulation condition from values that are only relative. Hipot test is the most common type of electrical safety test. This method allows conclusions to be drawn even if there. To do this for delta connected 9lead motors, remove the wirenuts from 4 and 7, 5 and 8, and 6 and 9.
Based on the test methodology chosen, refer to applicable standards or manufacturers literature for acceptable values. Ieee std 1122004, ieee standard test procedure for polyphase. It is shown, that for an individual assessment of the remaining insulation capability an insulation measurement in the g. For new equipment, the test should be done at about 60% to 80% of the manufacturers factory test voltage higher than the rated voltage and is available from the cable manufacturer. Readings should be within the specifications provided by the manufacturer. While the dielectric voltage withstand test is widely used, the real objective of the test is often misunderstood, which may lead to incomplete testing or misleading test results. How is ir testing done, in view of the fact that at least 80% of electrical maintenance and testing involves evaluating insulation integrity.
With 4,7 5,8 6,9 connected together, perform a standard continuity test between 1,2 1,3 2,3 to make sure there are no blown open windings within the motor. Timeresistance testing method this method is fairly independent of temperature and often. Standard for acceptance testing specifications for electrical. How to test a threephase motor with a megger hunker. Care shall be taken that flexible insulation is not unduly compressed. It involves applying the test voltage for a short time 30 or 60 seconds and noting the insulation resistance reading at. Facilities instructions, standards, and techniques volume 32 testing and maintenance of. Push the test button of the megger to generate the voltage. Insulation resistance test insulation resistance failure of an electric motor is one of the first signs that the motor is about to fail. Troubleshooting with insulation resistance test instruments.
Insulation resistance testing beginners guide testguy. Mar 26, 2017 push the test button of the megger to generate the voltage. These motors run conveyor belts, pumps, fans, and many other applications. Hipot testing verifies the integrity of highvoltage ac primary wire insulation in an electrical system to ensure that it is safe to operate. Use the following test procedure for pt insulation tests. A 1954 camera is ideal for all applications in the building, electrical maintenance and.